Skip to main content
  • Intra-operative Assessment of Repair

    The quality of the repair should first be evaluated after tying the ring sutures. Saline is injected into the ventricular cavity through the mitral valve. A symmetrical line of coaptation, parallel to the posterior part of the ring, with a normal ¾ to ¼ ratio of anterior to posterior leaflet within the orifice should be confirmed. An asymmetrical line of coaptation suggests the presence of residua...

  • Carpentier-Edwards Physio II - First Implantation

    OPERATION: Complex Barlow Mitral Valve Repair (P2 Resection with Detachment of P2 and Residual P1; Vertical and Horizontal Compression Followed by Sliding Plasty; Posterior Leaflet Flip to Correct A2 Prolapse and Reinforce P2 Repair; True Size 34 mm Carpentier-Edwards Physio II Ring)(Length: 8:09)New York, NY, February 23, 2009 -- David H. Adams, MD, Marie-Josee and Henry R. Kravis Professor and C...

  • Edwards Lifesciences Launches Carpentier-Edwards Physio II

    David H. Adams, MD, implanting the first Carpentier-Edwards Physio II ringIRVINE, CA, January 26, 2009 -- Edwards Lifesciences Corporation (NYSE: EW), the world leader in the science of heart valves, announced that the company is launching the Carpentier-Edwards Physio II mitral valve repair ring at the 45th annual meeting of the Society of Thoracic Surgeons (STS) in San Francisco. The new therapy...

  • Indications for Use

    The Carpentier-Edwards Physio II Annuloplasty Ring is intended for the correction of mitral valve insufficiency, or mixed mitral insufficiency and stenosis, where treatment does not necessitate a replacement of the natural mitral valve.The Carpentier-Edwards Physio II Annuloplasty Ring is intended to meet the challenges of modern valvuloplasty by maintaining the physiologic annular shape and motio...

  • Medtronic Tri-Ad Adams Tricuspid Annuloplasty Ring - First Implantation

    David H. Adams, MD (center), inventor of the Medtronic Tri-Ad Adams Tricuspid Annuloplasty Ring, with Robin Varghese, MD (right) and Irina Plotkina, RPA-C (left), performing the first U.S. implant.New York, NY, September 09, 2010 -- David H. Adams, MD, Marie-Josee and Henry R. Kravis Professor and Chairman of the Department of Cardiothoracic Surgery at The Mount Sinai Medical Center, has performed...

  • Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty Ring

    Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty RingCurrent heart valve repair (annuloplasty) rings and bands are designed for symmetric dilatation. The Carpentier-McCarthy-Adams IMR ETlogix Annuloplasty Ring is the first asymmetric ring designed to treat asymmetric dilatation. Corrects for the valvular insufficiency associated with Type IIIb mitral regurgitation. Decreased anteroposterior (AP)...